E-Class HYBRID PLUS Sedan model 213
as of 2016

-
12 V Battery, Left-hand drive
-
12 V Battery, Right-hand drive
-
High-voltage battery
-
HV charge socket
-
High-voltage disconnect device
-
Alternative high-voltage disconnect device, left-hand drive
-
Alternative high-voltage disconnect device, right-hand drive
Note
The alternative high-voltage disconnect device is only to be operated when the high-voltage disconnect device in the engine compartment is inaccessible.
Switch off the ignition before operating the high-voltage disconnect device and the alternative high-voltage disconnect device.
Legend
Airbag
Gas generator
Seat belt tensioner
Gas-filled strut
Fuel tank
Restraint systems control unit
12 V Battery
High-voltage battery
High-voltage components
High-voltage disconnect device
Alternative high-voltage disconnect device
Pedestrian protection
High-voltage disconnect device
The high-voltage disconnect device is located in the engine compartment next to the coolant expansion reservoir on the right (viewed in the direction of travel).

High-voltage disconnect device in engine compartment
Operate release (1) / Pull out switch (2)
Alternative high-voltage disconnect device
The alternative high-voltage disconnect device is located under the cover of the fuse box on the left of the cockpit. It is marked with an information label.
Information label on alternative high voltage disconnect device
Remove cover (1) of fuse box / Cut line at marked location (2)
Vehicle identification
-
HV charge socket
-
Left of trunk lid