Startseite
Zurück

E-Class HYBRID PLUS Sedan model 213

as of 2016


  • 12 V Battery, Left-hand drive

  • 12 V Battery, Right-hand drive

  • High-voltage battery

  • HV charge socket

  • High-voltage disconnect device

  • Alternative high-voltage disconnect device, left-hand drive

  • Alternative high-voltage disconnect device, right-hand drive

Note

The alternative high-voltage disconnect device is only to be operated when the high-voltage disconnect device in the engine compartment is inaccessible.

Switch off the ignition before operating the high-voltage disconnect device and the alternative high-voltage disconnect device.

Legend

  • Airbag

  • Gas generator

  • Seat belt tensioner

  • Gas-filled strut

  • Fuel tank

  • Restraint systems control unit

  • 12 V Battery

  • High-voltage battery

  • High-voltage components

  • High-voltage disconnect device

  • Alternative high-voltage disconnect device

  • Pedestrian protection

High-voltage disconnect device

The high-voltage disconnect device is located in the engine compartment next to the coolant expansion reservoir on the right (viewed in the direction of travel).

High-voltage disconnect device in engine compartment

Operate release (1) / Pull out switch (2)

Alternative high-voltage disconnect device

The alternative high-voltage disconnect device is located under the cover of the fuse box on the left of the cockpit. It is marked with an information label.

Information label on alternative high voltage disconnect device

Remove cover (1) of fuse box / Cut line at marked location (2)

Vehicle identification

  • HV charge socket

  • Left of trunk lid